AT^SIST retunrs ERROR? | Thales IoT Developer Community
December 9, 2014 - 3:23pm, 2902 views
Hello everyone,
We are working with HSE6 (revision 02.000) sending AT commands thru serial port. In our develop, we success sending small blocks of data (<1500 bytes), but now we need to open a transparent connection to send a huge amount of chars (about 3000) from our mobile device to a server in one block (no slices), because time matters...
But AT^SIST always return ERROR...:
AT^SICS=0,conType,GPRS0
OK
AT^SICS=0,user,MOVISTAR
OK
AT^SICS=0,passwd,MOVISTAR
OK
AT^SICS=0,apn,"movistar.es"
OK
AT^SISS=2,"srvType","HTTP"
OK
AT^SISS=2,"conId",0
OK
AT^SISS=2,"cmd","post"
OK
AT^SISS=2,"hcContLen","1"
OK
AT^SISS=2,"address","http://85.xx.***.x:8080/Mob***xx/Data***xx"
OK
AT^SISO=2
OK
^SIS: 2,0,2200,"Http 85.xx.***.x:8080"
^SISW: 2,1
AT^SIST=2
ERROR
Please, can you help us?
(if it helps, our company technical contact in Gemalto is Antonio López)
Thank you very much in advance!
Yours
Eduardo Muñoz
Grupo POAS
Hello Eduardo,
If you want to open a transparent connection you have to add "etx" parameter to the server address.
In your case this would be
AT^SISS=2,"address","http://85.xx.***.x:8080/Mob***xx/Data***xx;etx"
Best regards,
Bartłomiej